Direct Manufacturer in Chennai, India
Discuss project requirements directly with Floor Tech PVC Fabricators.
Manufactured in Chennai | All India Project Supply | 160mm PVC Pressure Relief Valve | As per BOQ / Drawing
Manufacturer for Canal Lining, Canal PCC Lining, Lined Canal Under-Drainage & Irrigation Hydraulic Structures
Floor Tech PVC Fabricators manufactures 160mm PVC Pressure Relief Valves / Pressure Release Valves for canal lining, canal PCC lining, lined canal under-drainage and irrigation hydraulic projects across India. This product is intended for approved pressure relief arrangements where trapped hydrostatic uplift pressure below the lining must be relieved through the designed drainage system.
Also specified as 160mm PVC pressure release valve, canal lining pressure relief valve, hydrostatic uplift pressure relief valve, uplift pressure relief valve and PVC Pressure Relief Valve for Canal PCC Lining.
Supporting pressure relief below concrete lining
Canal lining and hydraulic concrete structures can be damaged when trapped water below the lining creates hydrostatic uplift pressure. Floor Tech 160mm PVC Pressure Relief Valves support approved under-drainage arrangements by helping provide a controlled outlet for this pressure.
The valve is manufactured for engineering projects where product size, flange arrangement, perforation and installation details must follow the approved BOQ or project drawing.
Focused product for canal lining and under-drainage works
Floor Tech's 160mm PVC Pressure Relief Valve is manufactured for canal lining, canal PCC lining, lined canal under-drainage and hydraulic civil structures. This product is different from small spring-loaded, threaded, irrigation, cold room, industrial safety or pressure reducing valves commonly shown in general marketplace search results.
Specific product support instead of generic marketplace confusion
Marketplace listings often mix PVC pressure relief valves with many unrelated valve types. Floor Tech focuses this page on 160mm PVC Pressure Relief Valve for canal lining, canal PCC lining and lined canal under-drainage project requirements.
Discuss project requirements directly with Floor Tech PVC Fabricators.
Product information is focused on canal lining pressure relief valve applications, not unrelated valves.
Manufactured as per approved BOQ, drawing and project requirement.
Useful for canal lining, canal PCC lining and lined canal under-drainage requirements.
Installation arrangement details are shared based on approved BOQ and project drawing.
Supply enquiries are accepted from contractors and tender suppliers across India.
Share BOQ details, drawings and project information quickly on WhatsApp.
Project enquiries are welcomed from canal and irrigation contractors across India.
PRICE BASED ON PROJECT REQUIREMENT & QUANTITY
The price of a 160mm PVC Pressure Relief Valve depends on the project quantity, approved BOQ or drawing requirement, flange arrangement, perforation / top arrangement, packing requirement, delivery location and project schedule. For accurate pricing, send quantity, project location and BOQ / drawing on WhatsApp.
Share your BOQ, available drawing, required quantity and project details for quotation discussion.
Project supply for canal lining and irrigation works
Floor Tech accepts enquiries from canal contractors, irrigation contractors, government tender suppliers, civil contractors and project procurement teams across India. Share project location, quantity, BOQ item and required delivery schedule for quotation.
Engineering reference for lined canal drainage
IS 4558:1995 addresses under-drainage considerations for lined canals. Under-drainage may be required where high groundwater, a poor-draining subgrade, a practically impervious subgrade, seepage accumulation or rapid drawdown can create hydrostatic back pressure below the canal lining.
Pressure relief valves may form part of the approved pressure relief or under-drainage arrangement where they are specified by the project design. The valve helps provide a controlled discharge point within the designed drainage system.
Engineering note: Manufactured for lined canal under-drainage applications as per approved BOQ, drawing and project requirement. Pressure Relief Valve requirement, spacing, filter arrangement and installation should be decided by the project engineer / consultant.
Site conditions that may require pressure relief
Groundwater can create pressure below canal lining when the canal water level is low.
Seepage or leakage water may not dissipate quickly, causing pressure behind the lining.
Sudden reduction of canal water level can leave trapped back pressure below the lining.
Pressure Relief Valves may be required where the tender, BOQ, drawing or consultant specification calls for pressure relief arrangements.
Real product and project photographs
Engineering information for BOQ review
| Product name | 160mm PVC Pressure Relief Valve / Pressure Release Valve |
|---|---|
| Common use | Canal PCC lining, lined canal under-drainage, irrigation canals and hydraulic civil structures |
| Body material | PVC |
| Valve size | 160mm |
| Top | Perforated top / as per approved drawing |
| Arrangement | Flange type / project drawing type |
| Function | Helps provide a controlled discharge path for hydrostatic uplift / back pressure below canal lining when used within an approved under-drainage arrangement |
| Installation | Canal bed, side slope, drain line or filter pocket as per approved design |
| Supply type | Project quantity / bulk supply |
| Documents available | Brochure, drawing, technical data sheet, installation guide and quotation checklist, subject to project requirement |
| Quotation basis | BOQ / drawing / quantity / project location |
| Manufacturer | Floor Tech PVC Fabricators, Chennai, India |
Important note: Final spacing, placement, filter detail and installation method should be decided by the project engineer / consultant.
Visual explanation for contractors, consultants and procurement teams
The diagrams below are intended to explain the basic application of 160mm PVC Pressure Relief Valve in canal lining and lined canal under-drainage works. Final Pressure Relief Valve requirement, spacing, filter arrangement and installation must follow the approved BOQ, drawing and project engineer / consultant instruction.
Groundwater or seepage trapped below canal PCC lining can create upward hydrostatic pressure, especially during low canal water level or rapid drawdown conditions.
A specified pressure relief valve within the approved under-drainage arrangement helps provide a controlled discharge path for trapped water below the lining.
Depending on design, Pressure Relief Valves may be used with longitudinal drains, transverse drains, graded filter pockets, canal bed or side-slope arrangements.
These diagrams are for understanding only. Actual installation must follow approved drawing, BOQ and site engineer instruction.
Application within approved under-drainage design
160mm PVC Pressure Relief Valves may be installed with longitudinal drains, transverse drains or graded filter pockets depending on the approved design. For canal bed installation, the valve may be connected to the specified drain or positioned within an approved filter pocket. For side-slope installation, the valve position and surrounding filter arrangement should follow the consultant drawing and site conditions.
Typical fixing detail for customer understanding
Terminology used in project documents
Send your BOQ item, drawing and quantity for a project-specific quotation.
Consistent fabrication for project supply
| Ordinary Hole / Pipe Opening | Floor Tech 160mm PVC Pressure Relief Valve |
|---|---|
| Basic opening | Purpose-made fabricated Pressure Relief Valve assembly |
| No clear project documentation | Drawing / BOQ-based supply support |
| Inconsistent site fabrication | Repeatable manufacturing |
| Poor professional appearance | Project-ready product finish |
| Difficult to standardize for bulk quantity | Suitable for bulk project supply |
| May not match consultant requirement | Manufactured as per approved BOQ / drawing |
General sequence for project discussion
Note: This is only a general explanation. Actual installation must follow the approved project drawing, BOQ and site engineer’s instruction.
Responsibility of the project design team
Pressure relief valve requirement, spacing and location should be finalized by the project engineer or consultant based on water table position, subgrade type, canal section, under-drainage design and approved BOQ. Floor Tech manufactures and supplies 160mm PVC Pressure Relief Valves as per BOQ, drawing and project requirement.
Built around the way engineering projects are purchased
BOQ-based quotation, bulk production planning, project-location coordination and dispatch support.
Product details, commercial invoice support and supply information for tender and procurement review.
Technical product information and drawing-based discussion for specification and approval workflows.
Project-size supply, repeat production and requirement review for canal, dam and hydraulic works.
Technical trust for project procurement
Floor Tech serves enquiries for canal lining and hydraulic structure projects in Tamil Nadu, Karnataka, Andhra Pradesh, Telangana, Kerala, Maharashtra, Gujarat, Rajasthan, Madhya Pradesh, Bihar, Uttar Pradesh, Odisha and other Indian states.
Real proof for contractors and procurement teams
Floor Tech builds buyer confidence through direct manufacturing, real product photographs, BOQ-based supply support, and project-specific communication. Contractors and procurement teams can review product details, manufacturing proof, and dispatch-related information before placing bulk orders.




Documents for engineering and procurement review
Tell us which documents your consultant, contractor or procurement team requires. Available documents depend on the approved product configuration and project requirement.
Technical information for canal lining projects
Groundwater trapped beneath concrete lining can create upward pressure. A specified relief arrangement helps provide a controlled discharge path.
Floor Tech currently manufactures the 160mm variant for lined canal under-drainage and canal PCC lining applications as per approved BOQ or drawing.
The flange arrangement supports integration with the lining detail. Configuration is reviewed against the project requirement.
Applications include canal PCC lining and other civil hydraulic structures where trapped uplift pressure requires relief.
Copy-ready wording for contractor and consultant discussion
The wording below can be used for internal discussion with consultants, contractors and procurement teams. Final BOQ wording should be approved by the project engineer / consultant.
Supply of 160mm PVC Pressure Relief Valve for canal lining / lined canal under-drainage as per approved drawing, BOQ and project engineer's instruction.
Supply of 160mm PVC Pressure Relief Valve / Pressure Release Valve manufactured from PVC for canal PCC lining and lined canal under-drainage applications, suitable for relieving hydrostatic uplift / back pressure below lining through approved pressure relief arrangement. Installation location, spacing, filter pocket and drain connection shall be as per approved drawing and site engineer's instruction.
Required: 160mm PVC Pressure Relief Valve for canal lining project. Please quote based on quantity, project location, approved drawing / BOQ, delivery schedule, documentation requirement and packing requirement.
Specific searches for canal lining pressure relief valve buyers
Floor Tech supports project enquiries from contractors, consultants and procurement teams searching for 160mm PVC Pressure Relief Valve products for canal lining and lined canal under-drainage works.
Frequently asked technical and purchase questions
It forms part of an approved pressure relief or under-drainage arrangement and helps provide a controlled path for trapped groundwater below canal PCC lining to discharge.
No. Requirement depends on water table position, subgrade type and approved drainage design. In some free-draining conditions, pressure relief may not be necessary. Final decision should be by the project engineer or consultant.
Floor Tech currently manufactures 160mm PVC Pressure Relief Valves for canal lining and lined canal under-drainage applications.
Floor Tech can manufacture 160mm PVC Pressure Relief Valves for lined canal under-drainage applications as per approved BOQ, drawing and project requirement. Site layout, spacing and filter arrangement should be confirmed by the project engineer.
Depending on design, Pressure Relief Valves may be provided on longitudinal drains, transverse drains or in graded filter pockets below lining on side slopes.
Send the BOQ item, drawing, required quantity, project location and delivery schedule.
No. Spacing should be decided by the consultant / project engineer based on site conditions and design. Floor Tech supplies the valves as per approved requirement.
Yes, subject to approved drawing and BOQ details. Share whether the Pressure Relief Valve is required for canal bed, side slope, drain connection or filter pocket.
Yes. Floor Tech supports quantity-based production and repeat supply for approved canal and hydraulic civil project requirements.
Information needed for project review
Send project details for a technical quotation
Share your size, quantity, project location and BOQ or drawing. The form sends your enquiry and uploaded document directly to Floor Tech PVC Fabricators.
+91 8667 408 543 / +91 9444 332 444
floortechbalaji1960@gmail.com
Product view and installation explanation
Watch this short product video explaining the 160mm PVC Pressure Relief Valve for canal lining and hydrostatic uplift pressure relief applications.
Floor Tech PVC Fabricators manufactures 160mm PVC Pressure Relief Valves for lined canal under-drainage, canal PCC lining and irrigation hydraulic structures. The product helps relieve hydrostatic uplift pressure when used within an approved pressure relief arrangement.
Floor Tech PVC Fabricators manufactures 160mm PVC Pressure Relief Valve products as per customer-approved BOQ, drawing and project requirement. Hydraulic design, spacing, location and site installation arrangement are the responsibility of the project engineer / consultant.